FORD WM920 2009 Edition, July 31, 2009 GENERAL SPECIFICATION FOR PORT PLUG
In stock
Warning: Last items in stock!
Availability date: 2021-06-03
Description / Abstract:
FORD WM920, 2009 Edition, July 31, 2009 - GENERAL SPECIFICATION FOR PORT PLUG
This specification describes the dimensional and performance
requirements of an internally driven o-ring plug intended for
installation into a WM921, ISO 6149-1 or SAE J2244/1 port.
The plug original application was to seal hydraulic pressure to
63 MPa (630 Bar). Actual performance will vary when installed into
typical engine or transmission component material and when sealing
fluid other than hydraulic fluid. However, it is expected that the
sealing performance shall be sufficient for most engine and
transmission applications.
This plug is intended to seal engine oil, engine coolant and
transmission fluids between -30° and 150°C.
• The plug generally follows the dimensions of the ISO 6149-4
internal hex plug except:
• Plugs seats on the angled surface for improved sealing and
anti-loosening Smaller o-ring for better fit in the smaller groove
area
• Different o-ring material for increased temperature range and
fluid compatibility
• Hex size, s, increased for weight savings on larger size
plugs
• Hex chamfer diameter increased for better bit engagement
during automated assembly
• Hex drill diameter modified to provide relief for hex
broach
• Identification groove is not permitted.
• Recommended torque is reduced because of wedging action
created by the angles seat
• Permissible indent on pilot end for weight savings.
• Short pilot added to improve automated assembly.